Prometheus Juniper Junos OS exporter

Resources

Stars

4 stars

Watchers

4 watching

Forks

Repository files navigation

prometheus_network_exporter

Install Requirements

    pip install .

Tests

The unit tests run without a switch: the collectors read hand-written Junos replies from tests/fixtures/junos. They use documentation values only (RFC 5737, RFC 3849, RFC 5398, RFC 7042, RFC 2606); real device captures do not belong in this repository.

poetry install --with dev
poetry run black --check prometheus_network_exporter tests
poetry run flake8 prometheus_network_exporter tests
poetry run mypy
poetry run coverage run -m pytest
poetry run coverage report
promtool check rules prometheus/rules/*.yml
promtool test rules prometheus/tests/*.yml

GitHub Actions runs the same checks on every push and pull request. The tool versions are pinned in the dev group of pyproject.toml, so a local run reports the same findings. Coverage below 95 percent fails the run.

The Exporter

Configuration

The configuration is under /etc/prometheus-junos-exporter/config.yml you should change the configuration. No configuration means, that the current logged in user is used and its configuration. The SSH config is also used.

example

    python -m prometheus_network_exporter.app

Query a device

http://localhost:9332/device?target=device.example.com&module=default

module names a block of the config file; its metrics list selects the collectors. interface exports every interface, interface_specifics only the uplinks matching [gxe][et]-*/1/*; with both in one module interface wins. ospf and optics next to one of them add the OSPF neighbours and the optics to the interface collector, optics alone uses its own collector.

Drop a session

http://localhost:9332/unlock/device.example.com
http://localhost:9332/unlock/device.example.com?module=core_probe

Disconnects and drops the device objects of the target, all modules or only the one given; the next scrape logs in again. A scrape still running is waited for up to 10 seconds, after that the answer is 409 and the device object stays.

Optics, transceiver inventory and link endpoints

The optics collector reads module diagnostics and every reported optics-diagnostics-lane-values record from one RPC reply. The lane IDs and count come from the reply, never from the interface speed. Breakout ports keep their interface names, such as xe-0/1/1:2, and the reported lane ID. A non-breakout interface can have one, four or another number of reported lanes. A scalar-only reply does not establish the number of optical lanes.

Existing pyez_junos_interface_* optic metric names and labels remain. Missing readings, including explicit N/A, are no longer emitted as zero. A real zero remains zero; a reported -Inf remains -Inf. A single lane also supplies the legacy interface readings when the mapping is unambiguous (for breakout ports the suffix must match the lane ID). Multiple lanes are never averaged into one interface reading.

Additional metrics (prefix pyez_junos_interface_):

Metric Meaning
optics_available{interface} 1 for reported diagnostics, 0 for explicit N/A; absent when no usable diagnostic structure was returned
optics_reported_lanes{interface} number of explicitly reported lane records on this interface; absent for scalar-only or unavailable diagnostics, not total module lane capacity
lane_receiving_optic_power_dbm, lane_sending_optic_power_dbm RX/TX per interface and lane, with the existing description, MAC and speed labels
lane_receiving_optic_power_*, lane_sending_optic_power_* reported alarm/warning thresholds; lane-specific thresholds override common module thresholds
lane_laser_bias_current_milliamps, lane_laser_bias_*_threshold_milliamps bias current and thresholds per lane
lane_optics_alarm{interface,lane,alarm} reported lane alarm and warning flags, 1=on and 0=off
voltage_volts, voltage_*_threshold_volts module voltage and its alarm/warning thresholds
laser_bias_current_milliamps, laser_bias_*_threshold_milliamps correctly named aliases for the legacy bias metrics

The old voltage/bias metric names ending in _dbm are retained for existing dashboards, but their values are volts/milliamps, not dBm. The historical receiving_optic_power_low_alarm_threshold name still has no _dbm suffix; its lane metric is lane_receiving_optic_power_low_alarm_threshold_dbm like the other lane power metrics. The legacy sending_laser_fault_alarm uses 1=OK, 0=fault. Generic optics_alarm flags use 1=alarm, 0=clear and include additional flags Junos reports.

Two optional types add inventory and addressing:

Type Metrics Source and cost
transceivers pyez_junos_transceiver_info{module,manufacturer,part_number,serial_number,transceiver_type} and pyez_junos_interface_transceiver_info{interface,module} one chassis inventory RPC, one PIC detail RPC per PIC with transceivers, and one brief interface RPC
interface_addresses pyez_junos_interface_address_info{interface,parent_interface,routing_instance,address,family,prefix_length,network} one terse interface RPC, including logical units and IPv4/IPv6

module is the FPC/PIC/port location, e.g. 0/1/1. Several breakout interfaces map to the same module; serial numbers are not treated as unique keys. PIC detail supplies vendor name and part number when available; chassis inventory supplies serial number and reported type. Missing fields are blank, not inferred from the switch vendor. Unresolvable chassis locations are skipped. A failed PIC RPC leaves the chassis inventory usable. Each PIC is asked separately and reported as transceiver_pic_<fpc>_<pic> in pyez_junos_rpc_failed, so a PIC that rejects the RPC does not block the others. The part number is read from sfp-vendor-pno, the element Junos documents, or from sfp-vendor-part-number. If the chassis inventory reports two different modules at one location, that location is skipped and logged; the other modules are still exported.

Addresses without a known prefix retain a blank prefix_length and network. A peer address without a prefix is not interpreted as a subnet. An absent routing instance is unknown, not proof of the default instance. parent_interface is the containing physical interface from the XML; a LAG such as ae0 is not assigned to an arbitrary member. These are inputs for endpoint comparisons, not a proof that a cable or subnet is correct. Link-local and loopback addresses are not exported, nor the internal units lo0.16384 and up, bme* and jsrv*.

The existing lldp type now retains remote_port_id, remote_port_description and remote_port_subtype separately in pyez_junos_lldp_neighbor_info. Its existing remote_port label keeps the old description-first fallback. The extra labels create new LLDP series on upgrade; update joins that explicitly list all labels if needed.

Enable lldp, transceivers and interface_addresses in the relevant module's metrics list. For split core scrapes, add inventory/addressing only to core_slow; do not collect the same type in multiple modules for the same target. Access and legacy backbone modules need their own entries. The example config enables them in core_slow only. RPC replies with identical arguments are cached within each scrape, including brief interface replies shared by standalone optics and inventory. No additional optics RPC is issued per lane. The NETCONF login class must permit the new chassis/PIC and interface queries. Rejected RPCs remain visible in pyez_junos_rpc_failed.

These collectors report device data; they do not infer a DAC from a hostname, SFP-T label, N/A response or zero measurement. A lane record without an index or with an index already seen is skipped and logged instead of overwriting another lane.

Optical RPC replies are cached inside the exporter for 300 seconds by default. Existing Prometheus jobs and scrape intervals can stay unchanged: optics and transceivers remain in the modules already being scraped, while interface counters continue to refresh on every scrape. Split core targets continue to use core_slow; no additional optical job is needed.

junos.optics_interval_seconds changes this refresh interval (0 disables caching). Refresh happens on the first scrape after the interval expires, not on a background timer. A reply counts as expired a tenth of the interval early, so a scrape interval equal to the cache interval refreshes on every scrape instead of every second one. The cache only saves RPCs in modules scraped more often than the interval; core_slow is scraped every 300s and sets it to 0. The first scrape after an exporter restart also refreshes the data. Caches belong to the target/module's device object; do not enable the same optical collectors in multiple modules for a target. An expired reply is discarded before refresh. Failed queries do not extend its lifetime or return stale data; existing RPC failure metrics still apply.

pyez_junos_optics_cache_age_seconds and pyez_junos_optics_last_refresh_timestamp_seconds expose the source data's age/time, with RPC, interface selection and FPC/PIC labels. Prometheus sample timestamps alone indicate scrape time, not a fresh optical measurement. Module swaps and optical alarms can take until the next refresh to appear. This only caches optical diagnostics, chassis inventory and PIC details; interface traffic, addresses, status and LLDP are not delayed by this cache.

The alert JunosOpticsAlarm covers the interface flags, which include the flags of a single reported lane when its index matches the breakout port. JunosLaneOpticsAlarm covers every lane flag the interface does not raise itself: the receive and bias alarms of modules with several lanes, which Junos only reports per lane, and a breakout lane with a different index.

Inventory/PIC schemas and unbroken multi-lane modules still need validation on the deployed device models.

Routing metrics for Junos (BGP, OSPF, route tables, BFD)

The metric types bgp, ospf, routes and bfd export the state of the control plane. bgp and ospf are the cheap views of 1.2.5; the detail types cost ten more RPCs per scrape, among them show bgp neighbor and the LSDB, and belong into a slow module. Everything is prefixed with pyez_junos_:

Type Collectors Highlights
bgp legacy summary (bgp_is_up_status, prefix counters) one show bgp summary, as before 1.4
bgp_details bgp_peer_*, bgp_rib_*, bgp_group_* peer state as a state set, flap counter, per RIB prefix counts, message and error counters, uptime
ospf legacy neighbour state and uptime per interface two neighbour tables, as before 1.4
ospf_details statistics, ospf_neighbor_*, ospf_interface_*, ospf_* overview, ospf_database_*, ospf_routes; the same for ospf3_ neighbour state set and timers, interface cost and state, full SPF run counter, LSA counts, routes per next-hop interface
routes route_table_*, route_newest_age_seconds, route_young_routes, route_watch_* counts per table and protocol, time since the table changed, details for watched prefixes
bfd bfd_session_* session state, timers, diagnostics

An optional routing block in the module configures the route table dump:

  routing:
    tables: [inet.0, inet6.0]        # tables to dump for ages and watched prefixes
    watch: ["0.0.0.0/0", "::/0"]      # prefixes that get present/age/next-hop metrics
    young_route_seconds: 300          # a route younger than this counts as young

Two metrics report the health of the scrape itself: pyez_junos_rpc_failed lists RPCs Junos rejected, pyez_junos_xml_missing_fields counts fields a collector expected but did not find in the reply. A field that is missing is never exported as 0.

Deprecated: pyez_junos_bgp_prefixes_received_total and pyez_junos_bgp_prefixes_received_accepted_total are gauges declared as counters. They now sum over all RIBs of a peer; use pyez_junos_bgp_peer_rib_received_prefixes instead.

Control plane, forwarding plane and link metrics for Junos

These types exist to locate control plane stalls and packet loss on core switches. Every type has its own collector, so a module can be split by cost into a fast and a slow scrape job (see config/config.yml, modules core_probe, core_fast and core_slow).

Type Metrics (prefix pyez_junos_) Source
probe probe_success, probe_rpc_seconds show version; one cheap RPC for a 15s responsiveness job
routing_engine re_cpu_ratio{mode,window}, re_load_average, re_memory_utilization_ratio, re_temperature_celsius, re_up_seconds, re_info show chassis routing-engine
processes process_cpu_ratio, process_resident_bytes, process_threads, processes show system processes extensive, a fixed daemon list plus the top N
fpc fpc_state, fpc_cpu_ratio, fpc_cpu_interrupt_ratio, fpc_memory_utilization_ratio, fpc_temperature_celsius show chassis fpc
alarms alarms_active{source,class}, alarm_info, alarm_since_timestamp_seconds show chassis alarms, show system alarms
core_dumps core_dumps{process}, core_dump_newest_timestamp_seconds show system core-dumps
system system_time_seconds, system_booted_timestamp_seconds, last_commit_timestamp_seconds, last_commit_info{user}, storage_used_ratio, ntp_synced, ntp_offset_seconds show system uptime, show system storage, show ntp status
pfe pfe_statistics_total{section,counter}, pfe_statistics_rate show pfe statistics traffic
pfe_exceptions pfe_exceptions_total{type} show pfe statistics exceptions (not on every platform)
pfe_hw_tables pfe_hw_table_max_entries, pfe_hw_table_used_entries show pfe route summary hw
ddos ddos_packets_total, ddos_rate_pps, ddos_violations, ddos_violation_active show ddos-protection protocols statistics terse and violations
krt krt_queue_entries{queue}, krt_state{field} show krt queue, show krt state
rpd_memory rpd_task_memory{field} show task memory
fib fib_routes{table,family,type} show route forwarding-table summary
route_watch route_watch_* as with routes, one show route <prefix> exact per watched prefix and table of its address family replaces the watch list of the table dump
ldp ldp_session_state, ldp_session_up_seconds, ldp_neighbors, ldp_neighbor_hold_remaining_seconds show ldp session detail, show ldp neighbor
l2circuit l2circuit_up, l2circuit_up_transitions_total, l2circuit_info show l2circuit connections
pim pim_neighbors, pim_neighbor_up_seconds show pim neighbors
neighbor_tables arp_entries, nd_entries{state} show arp no-resolve, show ipv6 neighbors
interface_errors interface_errors_total{list,counter} (CRC, carrier transitions, MTU errors, resource errors, pause frames, ...), interface_queue_packets_total{queue,forwarding_class,kind} show interfaces extensive, only ports whose description matches
logical_interfaces logical_interface_{received,transmitted}_{bytes,packets}_total show interfaces lo0/irb
lacp lacp_member_mux_state, lacp_member_receive_state, lacp_member_distributing show lacp interfaces
lldp lldp_neighbors, lldp_neighbor_info show lldp neighbors
vxlan vxlan_remote_vteps, vxlan_remote_vtep_vnis, mac_table show ethernet-switching vxlan-tunnel-end-point remote, table summary

The optics type now also exports interface_optics_alarm{interface,alarm} from the same RPC as the optic values, so the transceivers are not polled twice.

An optional junos block in the module tunes these collectors:

  junos:
    rpc_timeout: 20                          # seconds per RPC, default 60
    keep_session: false                      # reuse the NETCONF session between scrapes (probe)
    keepalive_seconds: 30                    # SSH keepalive of a kept session, 0 for none
    exclusive_session: true                  # one session slot per switch across modules
    session_wait_seconds: 30                 # wait this long for the slot, else fail the scrape
    rpc_retry_seconds: 900                   # an RPC Junos rejected is not asked again for this long
    dns_ttl_seconds: 3600                    # reverse DNS of peers and neighbours, cached per device
    processes: [rpd, mgd, fxpc]              # always exported, default: common daemons
    process_top: 10                          # plus the N busiest processes
    extensive_interfaces: "[ex][et]-*"       # interface pattern for show interfaces extensive
    extensive_description: "^(Core|Server)"  # regex on the description, "" for all
    logical_interfaces: [lo0, irb]
    storage_mounts: "^(/|(/\\.mount)?(/var|/tmp|/config)?)$"

Scrape health for every module: pyez_junos_netconf_connect_seconds, pyez_junos_collector_duration_seconds{collector} and pyez_junos_collector_failed{collector}. A collector that raises an error no longer fails the whole scrape; only its own metrics are missing. Errors that mean the NETCONF session is gone still abort the scrape.

Device objects are cached per target and module, so one target can be scraped with several modules. To protect the routing engine, modules with exclusive_session (the default) share one session slot per switch: while one of them is connected, the others wait up to session_wait_seconds and then fail with DeviceBusy instead of opening a parallel session. The probe module opts out and keeps one long lived session (keep_session), so a 15s probe costs one small RPC instead of an SSH login and a new mgd process.

A kept session stays open until it fails. Before each scrape the exporter checks that its SSH transport is still alive; a session the device closed or lost with the link is dropped and replaced by a new login instead of failing the scrape. SSH keepalives every keepalive_seconds let a dead link show up between scrapes. pyez_junos_netconf_session_reused is 1 when a scrape used the kept session, pyez_junos_netconf_sessions_lost_total counts the kept sessions found dead. /unlock/<target>?module=<module> drops one module's session by hand.

--config selects another config file, which allows a second exporter instance next to the production one.

--worker N (default 90) is the number of devices one process scrapes at the same time; further scrapes wait for a free thread. --debug enables /memstats, the top memory allocations from tracemalloc.

--processes N starts N worker processes behind the one port. A Python process runs its collectors on one CPU core, however many threads it has; with the control plane modules of several cores one process is not enough and every other scrape waits behind them. Each target always lands in the same worker (hash of the hostname), so the connection pool, the session slot and a kept NETCONF session of a switch stay in one process. /metrics is served by the main process from the counters of every worker. When a worker dies the exporter exits and systemd restarts it. Use one process per CPU core the exporter may have, for example --processes 4.

Look for prometheus config

Example config for your prometheus can be found under prometheus/*.

For Enthusiasts

You can also configure the metrics definitions. If their are not enough Metrics. Configure config/metrics_definitions.yml and add functions to junos_exporter if the ouput is non trivial.

Interfaces, environment, IGMP, BGP, OSPF, route tables and BFD are supported. So only the Metrics Counter, Gauge and Info are implemented. Feel free to add Pull Requests to extend the implementation.