pip install .The unit tests run without a switch: the collectors read hand-written Junos
replies from tests/fixtures/junos. They use documentation values only
(RFC 5737, RFC 3849, RFC 5398, RFC 7042, RFC 2606); real device captures do
not belong in this repository.
poetry install --with dev
poetry run black --check prometheus_network_exporter tests
poetry run flake8 prometheus_network_exporter tests
poetry run mypy
poetry run coverage run -m pytest
poetry run coverage report
promtool check rules prometheus/rules/*.yml
promtool test rules prometheus/tests/*.ymlGitHub Actions runs the same checks on every push and pull request. The tool
versions are pinned in the dev group of pyproject.toml, so a local run
reports the same findings. Coverage below 95 percent fails the run.
The configuration is under /etc/prometheus-junos-exporter/config.yml you should change the configuration.
No configuration means, that the current logged in user is used and its configuration.
The SSH config is also used.
python -m prometheus_network_exporter.apphttp://localhost:9332/device?target=device.example.com&module=default
module names a block of the config file; its metrics list selects the
collectors. interface exports every interface, interface_specifics only
the uplinks matching [gxe][et]-*/1/*; with both in one module interface
wins. ospf and optics next to one of them add the OSPF neighbours and
the optics to the interface collector, optics alone uses its own collector.
http://localhost:9332/unlock/device.example.com
http://localhost:9332/unlock/device.example.com?module=core_probe
Disconnects and drops the device objects of the target, all modules or only the one given; the next scrape logs in again. A scrape still running is waited for up to 10 seconds, after that the answer is 409 and the device object stays.
The optics collector reads module diagnostics and every reported
optics-diagnostics-lane-values record from one RPC reply. The lane IDs and
count come from the reply, never from the interface speed. Breakout ports
keep their interface names, such as xe-0/1/1:2, and the reported lane ID.
A non-breakout interface can have one, four or another number of reported
lanes. A scalar-only reply does not establish the number of optical lanes.
Existing pyez_junos_interface_* optic metric names and labels remain.
Missing readings, including explicit N/A, are no longer emitted as zero.
A real zero remains zero; a reported -Inf remains -Inf. A single lane
also supplies the legacy interface readings when the mapping is unambiguous
(for breakout ports the suffix must match the lane ID). Multiple lanes are
never averaged into one interface reading.
Additional metrics (prefix pyez_junos_interface_):
| Metric | Meaning |
|---|---|
optics_available{interface} |
1 for reported diagnostics, 0 for explicit N/A; absent when no usable diagnostic structure was returned |
optics_reported_lanes{interface} |
number of explicitly reported lane records on this interface; absent for scalar-only or unavailable diagnostics, not total module lane capacity |
lane_receiving_optic_power_dbm, lane_sending_optic_power_dbm |
RX/TX per interface and lane, with the existing description, MAC and speed labels |
lane_receiving_optic_power_*, lane_sending_optic_power_* |
reported alarm/warning thresholds; lane-specific thresholds override common module thresholds |
lane_laser_bias_current_milliamps, lane_laser_bias_*_threshold_milliamps |
bias current and thresholds per lane |
lane_optics_alarm{interface,lane,alarm} |
reported lane alarm and warning flags, 1=on and 0=off |
voltage_volts, voltage_*_threshold_volts |
module voltage and its alarm/warning thresholds |
laser_bias_current_milliamps, laser_bias_*_threshold_milliamps |
correctly named aliases for the legacy bias metrics |
The old voltage/bias metric names ending in _dbm are retained for existing
dashboards, but their values are volts/milliamps, not dBm. The historical
receiving_optic_power_low_alarm_threshold name still has no _dbm suffix;
its lane metric is lane_receiving_optic_power_low_alarm_threshold_dbm like
the other lane power metrics. The legacy
sending_laser_fault_alarm uses 1=OK, 0=fault. Generic optics_alarm flags
use 1=alarm, 0=clear and include additional flags Junos reports.
Two optional types add inventory and addressing:
| Type | Metrics | Source and cost |
|---|---|---|
transceivers |
pyez_junos_transceiver_info{module,manufacturer,part_number,serial_number,transceiver_type} and pyez_junos_interface_transceiver_info{interface,module} |
one chassis inventory RPC, one PIC detail RPC per PIC with transceivers, and one brief interface RPC |
interface_addresses |
pyez_junos_interface_address_info{interface,parent_interface,routing_instance,address,family,prefix_length,network} |
one terse interface RPC, including logical units and IPv4/IPv6 |
module is the FPC/PIC/port location, e.g. 0/1/1. Several breakout
interfaces map to the same module; serial numbers are not treated as unique
keys. PIC detail supplies vendor name and part number when available;
chassis inventory supplies serial number and reported type. Missing fields
are blank, not inferred from the switch vendor. Unresolvable chassis
locations are skipped. A failed PIC RPC leaves the chassis inventory usable.
Each PIC is asked separately and reported as transceiver_pic_<fpc>_<pic> in
pyez_junos_rpc_failed, so a PIC that rejects the RPC does not block the
others. The part number is read from sfp-vendor-pno, the element Junos
documents, or from sfp-vendor-part-number.
If the chassis inventory reports two different modules at one location, that
location is skipped and logged; the other modules are still exported.
Addresses without a known prefix retain a blank prefix_length and
network. A peer address without a prefix is not interpreted as a subnet.
An absent routing instance is unknown, not proof of the default instance.
parent_interface is the containing physical interface from the XML;
a LAG such as ae0 is not assigned to an arbitrary member. These are inputs
for endpoint comparisons, not a proof that a cable or subnet is correct.
Link-local and loopback addresses are not exported, nor the internal units
lo0.16384 and up, bme* and jsrv*.
The existing lldp type now retains remote_port_id,
remote_port_description and remote_port_subtype separately in
pyez_junos_lldp_neighbor_info. Its existing remote_port label keeps the
old description-first fallback. The extra labels create new LLDP series
on upgrade; update joins that explicitly list all labels if needed.
Enable lldp, transceivers and interface_addresses in the relevant
module's metrics list. For split core scrapes, add inventory/addressing
only to core_slow; do not collect the same type in multiple modules for
the same target. Access and legacy backbone modules need their own entries.
The example config enables them in core_slow only. RPC replies with identical
arguments are cached within each scrape, including brief interface replies
shared by standalone optics and inventory. No additional optics RPC is
issued per lane. The NETCONF login class must permit the new chassis/PIC
and interface queries. Rejected RPCs remain visible in pyez_junos_rpc_failed.
These collectors report device data; they do not infer a DAC from a hostname, SFP-T label, N/A response or zero measurement. A lane record without an index or with an index already seen is skipped and logged instead of overwriting another lane.
Optical RPC replies are cached inside the exporter for 300 seconds by default.
Existing Prometheus jobs and scrape intervals can stay unchanged: optics
and transceivers remain in the modules already being scraped, while
interface counters continue to refresh on every scrape. Split core targets
continue to use core_slow; no additional optical job is needed.
junos.optics_interval_seconds changes this refresh interval (0 disables
caching). Refresh happens on the first scrape after the interval expires,
not on a background timer. A reply counts as expired a tenth of the interval
early, so a scrape interval equal to the cache interval refreshes on every
scrape instead of every second one. The cache only saves RPCs in modules
scraped more often than the interval; core_slow is scraped every 300s and
sets it to 0. The first scrape after an exporter restart also
refreshes the data. Caches belong to the target/module's device object;
do not enable the same optical collectors in multiple modules for a target.
An expired reply is discarded before refresh. Failed queries do not extend
its lifetime or return stale data; existing RPC failure metrics still apply.
pyez_junos_optics_cache_age_seconds and
pyez_junos_optics_last_refresh_timestamp_seconds expose the source data's
age/time, with RPC, interface selection and FPC/PIC labels. Prometheus sample
timestamps alone indicate scrape time, not a fresh optical measurement.
Module swaps and optical alarms can take until the next refresh to appear.
This only caches optical diagnostics, chassis inventory and PIC details;
interface traffic, addresses, status and LLDP are not delayed by this cache.
The alert JunosOpticsAlarm covers the interface flags, which include the
flags of a single reported lane when its index matches the breakout port.
JunosLaneOpticsAlarm covers every lane flag the interface does not raise
itself: the receive and bias alarms of modules with several lanes, which
Junos only reports per lane, and a breakout lane with a different index.
Inventory/PIC schemas and unbroken multi-lane modules still need validation on the deployed device models.
The metric types bgp, ospf, routes and bfd export the state of the
control plane. bgp and ospf are the cheap views of 1.2.5; the detail
types cost ten more RPCs per scrape, among them show bgp neighbor and the
LSDB, and belong into a slow module. Everything is prefixed with pyez_junos_:
| Type | Collectors | Highlights |
|---|---|---|
bgp |
legacy summary (bgp_is_up_status, prefix counters) |
one show bgp summary, as before 1.4 |
bgp_details |
bgp_peer_*, bgp_rib_*, bgp_group_* |
peer state as a state set, flap counter, per RIB prefix counts, message and error counters, uptime |
ospf |
legacy neighbour state and uptime per interface | two neighbour tables, as before 1.4 |
ospf_details |
statistics, ospf_neighbor_*, ospf_interface_*, ospf_* overview, ospf_database_*, ospf_routes; the same for ospf3_ |
neighbour state set and timers, interface cost and state, full SPF run counter, LSA counts, routes per next-hop interface |
routes |
route_table_*, route_newest_age_seconds, route_young_routes, route_watch_* |
counts per table and protocol, time since the table changed, details for watched prefixes |
bfd |
bfd_session_* |
session state, timers, diagnostics |
An optional routing block in the module configures the route table dump:
routing:
tables: [inet.0, inet6.0] # tables to dump for ages and watched prefixes
watch: ["0.0.0.0/0", "::/0"] # prefixes that get present/age/next-hop metrics
young_route_seconds: 300 # a route younger than this counts as youngTwo metrics report the health of the scrape itself: pyez_junos_rpc_failed
lists RPCs Junos rejected, pyez_junos_xml_missing_fields counts fields a
collector expected but did not find in the reply. A field that is missing is
never exported as 0.
Deprecated: pyez_junos_bgp_prefixes_received_total and
pyez_junos_bgp_prefixes_received_accepted_total are gauges declared as
counters. They now sum over all RIBs of a peer; use
pyez_junos_bgp_peer_rib_received_prefixes instead.
These types exist to locate control plane stalls and packet loss on core
switches. Every type has its own collector, so a module can be split by cost
into a fast and a slow scrape job (see config/config.yml, modules
core_probe, core_fast and core_slow).
| Type | Metrics (prefix pyez_junos_) |
Source |
|---|---|---|
probe |
probe_success, probe_rpc_seconds |
show version; one cheap RPC for a 15s responsiveness job |
routing_engine |
re_cpu_ratio{mode,window}, re_load_average, re_memory_utilization_ratio, re_temperature_celsius, re_up_seconds, re_info |
show chassis routing-engine |
processes |
process_cpu_ratio, process_resident_bytes, process_threads, processes |
show system processes extensive, a fixed daemon list plus the top N |
fpc |
fpc_state, fpc_cpu_ratio, fpc_cpu_interrupt_ratio, fpc_memory_utilization_ratio, fpc_temperature_celsius |
show chassis fpc |
alarms |
alarms_active{source,class}, alarm_info, alarm_since_timestamp_seconds |
show chassis alarms, show system alarms |
core_dumps |
core_dumps{process}, core_dump_newest_timestamp_seconds |
show system core-dumps |
system |
system_time_seconds, system_booted_timestamp_seconds, last_commit_timestamp_seconds, last_commit_info{user}, storage_used_ratio, ntp_synced, ntp_offset_seconds |
show system uptime, show system storage, show ntp status |
pfe |
pfe_statistics_total{section,counter}, pfe_statistics_rate |
show pfe statistics traffic |
pfe_exceptions |
pfe_exceptions_total{type} |
show pfe statistics exceptions (not on every platform) |
pfe_hw_tables |
pfe_hw_table_max_entries, pfe_hw_table_used_entries |
show pfe route summary hw |
ddos |
ddos_packets_total, ddos_rate_pps, ddos_violations, ddos_violation_active |
show ddos-protection protocols statistics terse and violations |
krt |
krt_queue_entries{queue}, krt_state{field} |
show krt queue, show krt state |
rpd_memory |
rpd_task_memory{field} |
show task memory |
fib |
fib_routes{table,family,type} |
show route forwarding-table summary |
route_watch |
route_watch_* as with routes, one show route <prefix> exact per watched prefix and table of its address family |
replaces the watch list of the table dump |
ldp |
ldp_session_state, ldp_session_up_seconds, ldp_neighbors, ldp_neighbor_hold_remaining_seconds |
show ldp session detail, show ldp neighbor |
l2circuit |
l2circuit_up, l2circuit_up_transitions_total, l2circuit_info |
show l2circuit connections |
pim |
pim_neighbors, pim_neighbor_up_seconds |
show pim neighbors |
neighbor_tables |
arp_entries, nd_entries{state} |
show arp no-resolve, show ipv6 neighbors |
interface_errors |
interface_errors_total{list,counter} (CRC, carrier transitions, MTU errors, resource errors, pause frames, ...), interface_queue_packets_total{queue,forwarding_class,kind} |
show interfaces extensive, only ports whose description matches |
logical_interfaces |
logical_interface_{received,transmitted}_{bytes,packets}_total |
show interfaces lo0/irb |
lacp |
lacp_member_mux_state, lacp_member_receive_state, lacp_member_distributing |
show lacp interfaces |
lldp |
lldp_neighbors, lldp_neighbor_info |
show lldp neighbors |
vxlan |
vxlan_remote_vteps, vxlan_remote_vtep_vnis, mac_table |
show ethernet-switching vxlan-tunnel-end-point remote, table summary |
The optics type now also exports interface_optics_alarm{interface,alarm}
from the same RPC as the optic values, so the transceivers are not polled twice.
An optional junos block in the module tunes these collectors:
junos:
rpc_timeout: 20 # seconds per RPC, default 60
keep_session: false # reuse the NETCONF session between scrapes (probe)
keepalive_seconds: 30 # SSH keepalive of a kept session, 0 for none
exclusive_session: true # one session slot per switch across modules
session_wait_seconds: 30 # wait this long for the slot, else fail the scrape
rpc_retry_seconds: 900 # an RPC Junos rejected is not asked again for this long
dns_ttl_seconds: 3600 # reverse DNS of peers and neighbours, cached per device
processes: [rpd, mgd, fxpc] # always exported, default: common daemons
process_top: 10 # plus the N busiest processes
extensive_interfaces: "[ex][et]-*" # interface pattern for show interfaces extensive
extensive_description: "^(Core|Server)" # regex on the description, "" for all
logical_interfaces: [lo0, irb]
storage_mounts: "^(/|(/\\.mount)?(/var|/tmp|/config)?)$"Scrape health for every module: pyez_junos_netconf_connect_seconds,
pyez_junos_collector_duration_seconds{collector} and
pyez_junos_collector_failed{collector}. A collector that raises an error
no longer fails the whole scrape; only its own metrics are missing. Errors
that mean the NETCONF session is gone still abort the scrape.
Device objects are cached per target and module, so one target can be
scraped with several modules. To protect the routing engine, modules with
exclusive_session (the default) share one session slot per switch: while
one of them is connected, the others wait up to session_wait_seconds and
then fail with DeviceBusy instead of opening a parallel session. The probe
module opts out and keeps one long lived session (keep_session), so a 15s
probe costs one small RPC instead of an SSH login and a new mgd process.
A kept session stays open until it fails. Before each scrape the exporter
checks that its SSH transport is still alive; a session the device closed
or lost with the link is dropped and replaced by a new login instead of
failing the scrape. SSH keepalives every keepalive_seconds let a dead link
show up between scrapes. pyez_junos_netconf_session_reused is 1 when a
scrape used the kept session, pyez_junos_netconf_sessions_lost_total
counts the kept sessions found dead. /unlock/<target>?module=<module>
drops one module's session by hand.
--config selects another config file, which allows a second exporter
instance next to the production one.
--worker N (default 90) is the number of devices one process scrapes at
the same time; further scrapes wait for a free thread. --debug enables
/memstats, the top memory allocations from tracemalloc.
--processes N starts N worker processes behind the one port. A Python
process runs its collectors on one CPU core, however many threads it has;
with the control plane modules of several cores one process is not enough
and every other scrape waits behind them. Each target always lands in the
same worker (hash of the hostname), so the connection pool, the session slot
and a kept NETCONF session of a switch stay in one process. /metrics is
served by the main process from the counters of every worker. When a worker
dies the exporter exits and systemd restarts it. Use one process per CPU
core the exporter may have, for example --processes 4.
Example config for your prometheus can be found under prometheus/*.
You can also configure the metrics definitions.
If their are not enough Metrics.
Configure config/metrics_definitions.yml and add functions to junos_exporter if the ouput is non trivial.
Interfaces, environment, IGMP, BGP, OSPF, route tables and BFD are supported. So only the Metrics Counter, Gauge and Info are implemented. Feel free to add Pull Requests to extend the implementation.