Repository navigation
Reentrant Execute harness + the file-sink leak it found (FT-9) - #454
Draft
ChrisonSimtian wants to merge 4 commits into
Draft
ChrisonSimtian wants to merge 4 commits into
ChrisonSimtian wants to merge 4 commits into
Conversation
ChrisonSimtian
force-pushed
the
engine/ft9-reentrancy-harness
branch
from
July 26, 2026 10:52
030c3fe to
7ac7242
Compare
5 tasks done
ChrisonSimtian
force-pushed
the
engine/ft9-reentrancy-harness
branch
from
September 4, 2026 10:06
7ac7242 to
5404766
Compare
ChrisonSimtian
force-pushed
the
engine/ft9-reentrancy-harness
branch
from
October 4, 2026 08:15
5404766 to
89a4884
Compare
ChrisonSimtian
force-pushed
the
engine/ft9-reentrancy-harness
branch
from
November 18, 2026 06:21
89a4884 to
e26e000
Compare
Logging.InMemorySink is now owned per-run by BuildContext.LogSink; the static InMemorySink.Instance becomes a facade over BuildContext.Current, with a lazy ambient fallback for logging outside a run. ConfigureInMemory wires the sink at the top of the run and WriteErrorsAndWarnings reads it at the end — both inside the scope — so a build's warnings and errors are discarded with its context instead of resurfacing in the next in-process invocation. The FT-1 InMemorySink.Clear() on dispose is dropped: there is no shared sink left to clear. Clear() itself stays for explicit resets. The sink constructor becomes internal so a context (and a spec) can create its own. Non-breaking — the public Logging surface is unchanged.
BuildContextSpecs mirrors the FT-4 parameter-service cases for the sink: the facade resolves the running context's sink, falls back to a stable ambient sink outside a run, and each run gets its own. Two existing cases assumed a process-wide sink and had to move with the mechanism: - Dispose_runs_the_per_run_teardown used the shared sink as its witness and fails once dispose stops clearing it — it becomes Log_events_do_not_carry_into_the_next_run, asserting the guarantee directly (the next run's sink never saw the previous run's events); - Disposing_a_superseded_context_leaves_the_shared_state_intact drops its sink witness and keeps the resolver-config one, since the sink is no longer shared state. InMemorySinkSpecs now exercises its own instance rather than the singleton, so it no longer needs the process-global collection or a normalising reset between cases.
9 tasks
…s over Host.WriteErrorsAndWarnings replaces Log.Logger with a console-only logger to re-render the run's warnings. The logger it replaced owns that run's file sinks, and assigning Log.Logger does not dispose it — so it leaked and kept `build.log` open for the life of the process. The next in-process run then threw in Logging.DeleteOldLogFiles trying to truncate that file, and did so silently: the throw lands before Configure has reassigned Log.Logger, so Execute's own Host.Error call went to an already-disposed logger. The run just returned the error exit code with no output. Any second run whose predecessor logged a warning hit this. Dispose the replaced logger. Nothing is lost — from that point the run logs through the console-only logger regardless, so the file sinks were already out of the picture.
Runs a fixture build end-to-end, twice in one process, and asserts what the de-static work promised: both runs succeed, the second gets its own context/parameter service/log sink, it opens on an empty sink, and the static facades inside a run point at that run. This is what the original FT-9 commit set out to do. Its unit-level assertions have since landed with the steps they belong to (FT-2 in Fallout-build#451, FT-4 in Fallout-build#452, FT-6 in Fallout-build#453), so what is left here is the end-to-end case they could not cover — and it immediately found the leaked file-sink logger fixed in the previous commit. Verified as a real guard: reverting that fix fails 4 of these 5 specs. Two process-wide inputs are pinned to make a build runnable under a test host — the argument parser (swapped and restored) and the statically-resolved root directory (asserted to carry the .fallout marker, since UpdateNotification prompts for input without it). Both are de-statification candidates in their own right.
ChrisonSimtian
force-pushed
the
engine/ft9-reentrancy-harness
branch
from
November 21, 2026 23:46
e26e000 to
565ef40
Compare
This branch has not been deployed
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Adds a test that runs a real build twice in one process, and fixes the log-file leak that test found.
Part of #315 (FT-9, #314).
Stacked on #453 (FT-6). The diff includes its two commits until it merges. Review only the top two commits (the leak fix and the harness). FT-1, FT-2 and FT-4 have already landed.
What changed
Host.WriteErrorsAndWarningsreplacesLog.Loggerto re-print warnings. SettingLog.Loggerdoes not dispose the old logger. That logger owns the run's file sinks, sobuild.logstayed open. The next run in the same process then failed to reset the file and returned the error exit code with no message. The fix disposes the old logger. Nothing is lost, because the run logs through the new logger from that point.BuildManagerReentrancySpecsruns a small build throughBuildManager.Executetwice. It checks that:BuildContext,ParameterServiceand in-memory sink;GitRepositoryWorktreeSpecsjoins the sharedProcessGlobalStateCollection. It logs through the process-wideLogand could add lines to a concurrent run's sink.Why
The earlier FT-9 spec only tested
BuildContextdirectly. Nothing ran two full builds in one process, and that is the case the per-run state work is for.Limits of the test
EnvironmentInfo.ArgumentParserandFalloutBuild.RootDirectory. Making them per-run is a separate change.Verification
A_second_run_in_the_same_process_also_succeeds. The others fail after it because the leaked file stays open.Fallout.Build.Specs: 275 of 278 pass. The 3 failures areGitRepositoryWorktreeSpecsthat need a checkout whose remote isFallout-build/Fallout.