Skip to content

Docs: half-and-half images in the home page "From real scans" strip - #983

Merged
AnderBiguri merged 1 commit into
masterfrom
docs/home-strip-panels
Nov 28, 2026
Merged

AnderBiguri merged 1 commit into
masterfrom
docs/home-strip-panels

Conversation

@AnderBiguri

Copy link
Copy Markdown
Member

What does this PR do?

Item 5 of the 28 Nov website review: the home page's "From real scans" images were whole multi-panel figures (six heads, six synchrotron slices), which are busy at thumbnail size.

  • Each image now shows one slice split down the middle, like the slider above it. A simple method is on the left and an iterative one on the right, with a thin orange line between them. This keeps the point that TIGRE has many algorithms.
    • Clinical cone-beam CT: FDK and OS-SART.
    • Synchrotron: FBP and OS-ASD-POCS.
    • Helical micro-CT: FDK and FISTA-TV.
    • Neutron tomography: FDK and SIRT.
  • The halves come from panels of the same figures the gallery uses (2025 v3 paper, CC BY 4.0). They are aligned by correlation, with shifts of 2 px or less, and centred on black at 640×480.
  • A small grey line under each image names the two methods, and the alt text says which is on which side.
  • Size: 90 KB for the four (was 117 KB).

The paper shows the neutron FDK panel on a grey background, so that panel's edge is visible on the left; it is left as published.

Which parts of TIGRE does it touch?

  • Python
  • MATLAB
  • CUDA kernels (Common/CUDA)
  • Docs / demos only

Checklist

  • Tested locally: sphinx-build -W --keep-going passes; checked by screenshots.
  • Added or updated tests where it makes sense: none needed, docs only.
  • Demos and docs updated if user-facing behaviour changed.
  • Entry added to changelog.md: none, the website is not part of a release.

Test environment

  • GPU / CUDA: not needed, docs build only.
  • OS: Linux.

An AI coding agent (Claude) wrote this change. The maintainer asked for the half-and-half images and reviewed screenshots before it was pushed.

🤖 Generated with Claude Code

https://claude.ai/code/session_01L6n1VKzc1MHHkq9EuERTD3

Each image showed a whole multi-panel figure (six heads, six synchrotron
slices), which is busy at thumbnail size. Each now shows one slice split down
the middle like the slider above: a simple method on the left, an iterative
one on the right, with a thin orange line, aligned by correlation (shifts of
2 px or less). The two methods are named under each image and in its alt
text: FDK and OS-SART (clinical CBCT), FBP and OS-ASD-POCS (synchrotron), FDK
and FISTA-TV (helical micro-CT), FDK and SIRT (neutron). 90 KB for the four.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01L6n1VKzc1MHHkq9EuERTD3
@AnderBiguri
AnderBiguri merged commit a0eed40 into master Nov 28, 2026
2 checks passed
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

2 participants